G-Glass Fiberglass Duplex

G-Glass Fiberglass. Individual conductors are insulated with general purpose fiberglass and with an overall fiberglass jacket. Designed for continuous use in temperatures rating up to 950 Degrees F (510 Degrees C). Fiberglass is flexible and can be ordered twisted with reduced itch TuffbondTM construction. G-Glass can be used in industry applications such as heat treatment, metal forgings, metal qualifications, aluminum.

Applications
Available Options
Features
Specifications
Ordering Code
    • Heat Treatment
    • Temperature Sensors
    • Steel and Aluminum Industry
    • Plastic Processing Equipment
    • Furnace Surveys
    • Testing
    • Reduced Itch TuffbondTM Impregnation on Singles
    • Stabilized Type K & Type E Conductors
    • Fused PTFE Tape Moisture Barrier
    • Double Glass Braid Insulation
    • Twisted/Shielded Pair
    • Metal Coverings
    • Tighter than Special Limit Accuracy Tolerances
    • Special Color Codes
    • Calibration Test Reports
    • Flexible with good moisture, chemical and abrasion resistance
    • Provides accurate temperature measurement with high temperature stability
    • According to AMS2750E load thermocouple made from calibrated spool thermocouple wire up to 2000 feet do not need to be calibrated individually
    • According to AMS2750E on single use load thermocouple SAT test is not required (special procedure on instrument calibration is to be implemented)
    • Very useful as TUS test thermocouple
    • TE Wire & Cable certificate of calibration is issued from an ISO17025 lab
  • Conductors: Solid or stranded thermocouple wire per ASTM E230 & ANSI MC96.1

    Insulation: Braided fiberglass with high temperature impregnation* (24 to 30 AWG Served Glass)

    Construction: Parallel conductors

    Jacket: Braided fiberglass with high temperature impregnation*

    Operating Temperature: +950F (+510C) continuous +1200F (+650C) single exposure

    Limits of Error: Conforms to ASTM E230, IEC 584 and ANSI MC 96.1

    Color Code: Conforms to ASTM E230 and ANSI MC96.1 (International Color Codes Available)

    *Impregnation maintained to +400F (+200C)

  • G/G [( 1 )] – [( 2 )] [( 3 )] – [( 4 )]

    1) Optional Metal Covering

    S= Stainless Steel Braid

    CU = Tinned Copper Braid

    I = Inconel Braid

    X = Half-Oval Galvanized Steel

    2) Wire Size AWG

    Available from 14 AWG to 30 AWG

    3) Add (F) for Stranded Wire

    Example: 24F = 24 AWG 7-Strand Conductor

    4) Calibration Grade Designation

    Type K, N, E, J, T available in Standard Limits, Special Limits and Accutherm Grade

    Single Letter = standard limits

    Double Letter = special limits

    Triple Letter = Accutherm limits (half class 1)