HG/HG Vitreous Silica Heavy Build Fiber

Vitreous Silica fiber designed for extreme temperature applications. Vitreous Silica fiber in this design is braided with thicker insulation on the individual conductors and the jacket giving a continuous temperature rating up to 1800 Degrees F (982 Degrees C). The vitreous silica fiber is flexible throughout the extended temperature range but is not recommended for application that are highly abrasive in high temperatures. The high temperature limit of Vitreous Silica allows it to be used in areas where temperature is higher than the upper limit of fiberglass braided wires.

Applications
Available Options
Features
Specifications
Ordering Code
    • Heat Treatment
    • Component Testing
    • Steel and Aluminum Industry
    • Metals Production
    • Furnace Surveys
    • No tracers
    • Impregnated Jacket
    • Stabilized Type K & Type E Conductors
    • Metal Coverings
    • Tighter Than Special Limit Accuracy Tolerances
    • Calibration Test Reports
    • Flexible – continuous use up to 1800F(982C)
    • Provides accurate temperature measurement
    • According to AMS2750E load thermocouple made from calibrated spool thermocouple wire up to 2000 feet do not need to be calibrated individually
    • According to AMS2750E on single use load thermocouple SAT test is not required (special procedure on instrument calibration is to be implemented)
    • Very useful as TUS test thermocouple
    • TE Wire & Cable certificate of calibration is issued from an ISO17025 lab

     

  • Conductors: Solid or stranded thermocouple wire per ASTM E230 & ANSI MC96.1

    Insulation: Braided vitreous silica fiber

    Construction: Parallel conductors

    Jacket: Braided vitreous silica fiber

    Operating Temperature: +1800F (+982C) continuous +2000F (+1093C) single exposure

    Limits of Error: Conforms to ASTM E230, IEC 584 and ANSI MC 96.1

    Color Code: Supplied white without saturants and with red tracer in negative leg

     

  • HG/HG [( 1 )] – [( 2 )] [( 3 )] – [(  4  )]

    1) Optional Metal Covering

    S= Stainless Steel Braid

    CU = Tinned Copper Braid

    I = Inconel Braid

    X = Half-Oval Galvanized Steel

    2) Wire Size AWG

    Available from 12 AWG  to 24F

    3) Add (F) for Stranded Wire

    Example: 24F = 24 AWG 7-Strand Conductor

    4) Calibration Grade Designation

    Type K, N, E, J, T available in Standard Limits, Special Limits and Accutherm Grade

    Single Letter = standard limits

    Double Letter = special limits

    Triple Letter = Accutherm limits (half class 1)